*price, EXW ELPOS Ltd., Požega, Croatia, valid from 1.9.2024.
[wooscp id="7864"]

SSAP type heating cables are classic, twin conductor (two cores) heating cables of round cross-section with an electro-resistant alloy core and a return copper conductor. Their main feature is the possibility of one-sided power supply. They are designed for loads up to a maximum of 25 W/m.

The lengths of cables can range from 5 m to 165 m (for standards voltage of 230 V), and depend on the application and needs of the heated object. For specific information about this type of heater, related to solving one of your electric heating problems don’t hesitate to send us an inquiry!

Technical specification

type: resistive-wire, twin conductor heater
core: electro-resistant alloy
maximum load: 25 W/m
maximum allowable temperature: 90 °C
cross section: circular, Φ 6 to 7.5 mm
advantage: water and ice resistance
application: heating of pipelines, gutters, external and internal surfaces
specific resistances of heating cables ρ [Ω/m]: 0.115; 0.135; 0.175; 0.235; 0.285; 0.335; 0.395; 0.485; 0.555; 0.610; 0.685; 0.855; 1,035; 1,335; 1,505; 1,635; 2,075; 2,335; 2,935; 4,035; 5,035; 6,135; 8,035; 12,035; 18,035; 32,035; 40,035; 100,035

Documentation download:

Reviews

There are no reviews yet.

Be the first to review “Resistive wire heating type SSAP”